Thursday, March 11, 1999

How To Make Your Basement Suite Legal


DISCLAIMER: THIS INFORMATION WAS GATHERED FROM ONTARIO MUNICIPAL SOURCES. THESE BYLAWS MAY NOT APPLY TO YOUR AREA. PLEASE CHECK WITH YOUR CITY.


In a city like Toronto, where the apartment vacancy rate is low and real estate values are

high, many people rely on the rental income from a basement apartment to give them the

edge they need to own a home. But is it a ‘legal’ apartment? If not, how can it be made

‘legal’? In the process of legalizing the apartment, will I be inviting ‘trouble’? What if the

‘city’ prescribes improvements that are prohibitively expensive? What if the ‘city’

decides that I can’t have an apartment?


Catch 22


Homeowners with a basement apartment would like to find out what it would take to

‘legalize’ the apartment, but they want to find this out without tipping off the authorities.

The only way to know for sure what will be required is to have inspections done by the

appropriate authorities.

This report sheds some light on this complicated subject. We will look at basement

Apartments including –

  • Key concepts
  • The history
  • The evaluation process
  • Four key issues
  • The rules
  • Inspections and their costs
  • Where to get more information


Definitions


Is it ‘legal’?


‘Legal’ involves five separate issues including –

  • Do the local bylaws permit you to have a basement apartment?
  • Does the apartment comply with the fire code?
  • Does the apartment comply with basic building code requirements?
  • Does the apartment comply with basic electrical safety requirements?
  • Has the apartment been ‘registered’?

We will look at these issues more closely.


Building code vs. fire code


The Building Code prescribes minimum requirements for the construction of buildings.

For the most part, the Building Code is a code that applies only the day the house was

built. The code changes over the years, but we don’t have to keep changing our houses to

comply with the code. The code does not apply ‘retroactively’.

The Fire Code is a subset of the Building Code. It prescribes construction and safety

issues as they relate to how the building is required to perform should it catch fire. A

significant distinction with the fire code is that it can apply retroactively.


Basement retrofit


Now that we know that the Fire Code applies retroactively, we can see where the phrase

“basement retrofit” comes from. A new Fire Code was developed that applies to

basement apartments. The code applies retroactively, so all basement apartments whether

existing or new must comply with the new Fire Code. All owners of homes with

basement apartments were given a period of time to upgrade their homes to comply with

the new Fire Code. This ‘grace period’ has long since passed.


Certificate of compliance


All basement apartments have to be inspected to verify that they are in compliance. Once

this has been verified and any improvements completed, the apartment is given a

‘certificate of compliance’.


Bylaw


We mention this term here to make sure that we don’t confuse bylaws with building

codes. Bylaw in the context of basement apartments refers to whether you are permitted

to have a basement apartment in your area and any special conditions involved. Bylaws

are set by municipalities to keep people from being a nuisance to their neighbours. Codes

are health and safety rules to protect occupants.


Basement Apartments – The History


Prior to 1993, there was little to worry about. After 1993, a permit was required to change

a home from single family to multi-family.

In 1994, the NDP government in Ontario said that we could ignore local bylaws that

prohibited second dwelling units in houses if certain conditions were met.

In 1994, the province set new Fire Code rules for basement apartments. A deadline was

established for all existing basement apartments to upgrade to the new fire code.

Upgrading to comply with the new fire code is called a “retrofit”. The owners were

allowed to apply for an extension for up to two years past the deadline if they had

financial or logistical obstacles. Even with the extension, the deadlines have long since

passed.

In 1995, the provincial Conservative government told municipalities that they could

enforce their bylaws regarding basement apartments. A grand-fathering clause says that

apartments existing before November 1995 do not have to meet local bylaws.

The Evaluation Process

NEW UNITS

If you are thinking of adding a basement apartment here is the procedure –

Check the Zoning Bylaw at City Hall Buildings Division to find out if basement

apartments are allowed.

You would then apply for a building permit. Keep in mind that you will have to

comply with today’s building codes.


EXISTING UNITS


This report will focus on existing homes with a single basement apartment.

The first step is to check with Municipal Property Standards or the Fire Department

for a Certificate of Compliance. If there is one, you are done!

If the unit is not registered, you need to do some more work

Verify that zoning bylaws permit a basement apartment. In most cases they do.

The next step is to have the fire department inspect the home. They will verify

compliance with the fire code. This is the most daunting part of the process because

any deficiencies will have to be corrected by order of the fire marshal.


The next step is to have the Electrical Safety Authority (which used to be called

Ontario Hydro Inspection Department) inspect the electrical system. Once again, you

will be required to make any improvements that are prescribed.

If the apartment unit passes the inspections, the unit can be registered with Municipal

(Property) Standards (If not, improvements may cost $15,000 or more).


Four Key Elements


There are four key areas regarding fire code compliance. They all have to do with the

safety of the occupants –

Fire containment.

Mean of egress.

Fire detection and alarms.

Electrical safety.

Let’s look at each of these.


1. Fire Containment


The goal is to contain the fire in the unit that the fire started, long enough to get all of the

occupants out of the house. This means that any walls, floors, ceilings and doors between

units should control the fire for at least a few minutes. These components are given

‘ratings’ of how long they will survive a direct fire before burning through. A 30 minute

rating means that the component will control the fire for at least 30 minutes.

The typical requirement is a 30 minute separation between the units.

Drywall and plaster are acceptable. but suspended (T-bar type) ceilings are not.

The ceiling must be continuous. For example, this means that you can’t have exposed

joists in the furnace room – this area has to be drywalled or plastered as well.

Doors should be solid wood or metal – at least 1¾ inch thick.


2. Means of Egress - Escaping the home


The goal is to allow the occupants to get out of the house if there is a fire. There are two

common situations; either each unit has its own exit, or there is a common exit. If each

unit has its own exit, you are all set. If the units share an exit, it is more complicated.

A common exit is allowed if it is ‘fire separated’ from both of the units with a 30 minute

rating. If the common exit is not appropriately fire separated, you can still use this

common exit as long as there is a second exit from each dwelling unit and the fire alarms

are interconnected (if one alarms, the others will alarm as well). Here is an example:

There is a common exit area but the common area does not have a 30 minute fire

separation between both of the units. If there is an ‘acceptable’ window for an escape

route and the smoke alarms are interconnected, we are all set.

What is an acceptable window?

The windowsill must be within 3 feet of grade. We don’t want people jumping and breaking a leg.

The smallest dimension is 18 inches.

The opening is at least 600 square inches (30 inches by 20 inches for example)

If there is a window well on a basement window, it must extend 3 feet out from the house wall, to allow room to crawl out.


3. Fire detection


All units must have smoke alarms. The owner of the property is responsible for ensuring

that there are smoke alarms and that they are maintained. The smoke alarms do not have

to be interconnected unless the fire separation to the common exit area does not have a 30

minute rating (Note: It must have at least a 15 minute rating).

A carbon monoxide detector (CO detector) may be required by the city.


4. Electrical Safety


An electrical inspection by the Electrical Safety Authority is required. The Electrical

Safety Authority used to be called Ontario Hydro Inspection Department. All deficiencies

must be addressed.


General Rules


Here are a few rules that your apartment must meet.

All bathrooms need either a window or an exhaust fan

If there is a parking spot for one of the units, there must also be a parking spot for the other unit (yes, you read it correctly!)

The minimum ceiling height is 6 feet 5 inches

The entrance door size must be at least 32 inches by 78 inches


Inspections and their costs


As we already pointed out, two inspections are required, fire code inspection and

electrical safety inspection.

Once the inspections are done, you will be required to make the prescribed

improvements. Improvements may be minor, but can cost $15,000 or more.

There is lots of room for the inspectors to be more or less ‘strict’. In municipalities that

encourage basement apartments, the inspection may be lest strict. In municipalities that

discourage basement apartments, the inspection may be more strict.

Inspections for fire code compliance cost between $120 and $300.

Inspections for electrical safety cost $72.


The consequences


If you are going to represent the property as two family, verify that it is registered with

Municipal Property Standards. Failure to comply can result in a $25,000 fine and oneyear

jail term.

No comments: